Customized: | Non-Customized |
---|---|
Certification: | ISO9001 |
Brand: | AC |
Display Type: | Touch Screen |
Power: | 3p/380V/50Hz |
Machine Current: | 180A |
Customization: |
---|
Suppliers with verified business licenses
100-96 Specifications | |||
Sr. | Parts | Specification | Parameters |
1 | Model | 100-96 | |
2 | Power | 3P 380V,50HZ | |
Machine Current | 180A | ||
3 | Hot Media | High quality synthetic heat transfer oil (eg. Solutia T66) | |
4 | Max. Temp. | 280ºC | |
5 | Min. Temp. | Inlet Water Temp.+25ºC | |
6 | Control Way | Computer PC board self-optimizing microprocessor | |
7 | Heating Power | 96KW | |
8 | Circulating Hot Oil Pump | Model | RY65-40-200 |
Power | 7.5KW | ||
9 | Head | 54M | |
Flow Rate | 25m3/h | ||
10 | Interface | Hot media imp. and exp. | DN50(Flange interface) |
oil drain | 1/2"(Threaded interface) | ||
11 | Material | Circulation pipeline | 20# GB/T8163 Flange SO HG20592 |
12 | Thermostat | Model | England WEST P6100 Accuracy PID ±1ºC |
Conditioning action | Heating and cooling dual PID control | ||
Thermometer | Type K Thermocouple Accuracy Class A (±0.15+0.005|t|) | ||
Show status | Set value and actual value are displayed separately | ||
Output selection | Contactor output | ||
13 | Safety protection device | abnormal temperature | When the circulating oil temperature exceeds the upper limit value, the main power supply is cut off |
Power reverse phase | Mains phase detection prevents pump reversal and alarm indication | ||
Pump overload | Thermal relay protects pump overload and alarm indication | ||
Oil shortage protection | The oil tank detects the oil level according to the liquid level switch to prevent oil shortage and gives an alarm indication | ||
abnormal heating | Contactor stuck, abnormal heating alarm and indication | ||
pipe blockage | BY-PASS pressure relief circuit protects the pump | ||
abnormal pressure | Automatically stop heating when the system pressure is abnormal | ||
Exhaust function | When the equipment is running at 120 degrees, it will automatically stop heating and timing exhaust function | ||
Short circuit - over temp. | Air switch - trip | ||
16 | Rack Dimensions | Case(mm) | L1650*W600*H1400(Equipment without electrical parts) |
Pipe volume(L) | About47L | ||
expansion tank | 250L | ||
17 | Total Weight(kg) | 450 |
Mechanical Part | ||||
Sr. | Spare parts | Specification | Qty | Brand |
1 | Pump | SAP65-40-200 | 1 | (OEM) |
2 | Heating Tube | 3P 380V (48KW) | 2 | (OEM) |
3 | Pressure gauge | 10KG | 1 | (OEM) |
4 | Pressure Switch | PSeries (Automatic Reset Type) | 1 | (OEM) |
5 | Thermometer | PT100/Type K thermocouple | 2 | Taiwan Min Yang |
6 | Shut-off valve | DN50 | 2 | (OEM) |
7 | Piping system | Pipeline 20# steel integral molding Flange HG20592 PN16 |
1 | (OEM) |
8 | Pipe insulation | Foam glass flame retardant material | 1 | (OEM) |
9 | High temperature exhaust solenoid valve | ZQD-15 | 1 | Baode |
Electrical Part | ||||
1 | Controller | AT430 | 1 | (OEM) |
2 | Air Switch | 200A | 1 | LS |
3 | Heating Contactor | 3RT | 8 | Siemens |
4 | Pump Contactor | 3RT | 1 | Siemens |
5 | Microcomputer control board | Five-channel integrated control system | 1 | (OEM) |
6 | Breaker | 2P6A | 1 | Siemens |
7 | Over-temp. Thermostat | AI-207 | 2 | (OEM) |
8 | Intermediate relay | 220V2P | 1 | Weidmüller |
9 | Pump overload | TA25DU | 1 | Siemens |
10 | Siren | 220V 85+db | 1 | NanYi |
11 | Release | 220V | 1 | LS |
12 | reverse phase protector | DPA51CM44 | 1 | Swiss Galleries |
1. It is recommended to select the working point of the pump: the flow rate is 25 cubic meters per hour, and the lift is 54 meters; 2. The performance curve corresponds to the oil at 20 degrees at normal transport speed. The error of head and flow is ±10%, and the performance error is ±10%; 3. The performance of the pump varies with the specific gravity and density of the fluid medium being transported; 4. The above curve is the premise that the pump inlet is not less than DN65; the outlet is not less than DN50; |
|||||||||||||||||||||||||||||||||
Necessary conditions to be provided at the installation site | |||||||||||||||||||||||||||||||||
1,Water pressure and water quality: Water heaters with cooling function must provide cooling water at the site of use, water pressure requirements: 0.15-0.3Mpa; To prevent damage to the heat exchanger built into the heater due to blockage, the water must meet the following requirements:
2,Power cord connection: The power cord needs to use 3*4mm2+1*2.2mm2 cable, which is provided by the buyer, and the power cord must be grounded! 3,Hot media: Solutia No. t66 heat transfer oil 4,Working environment: The working environment temperature of the equipment is 18ºC-40ºC; relative humidity: 50%-80%, ensure good ventilation; temperature difference: under ±4ºC/h, the equipment works 7 days a week, 24 hours a day. |
Suppliers with verified business licenses